Right-sized equipment still fails if the ducts starve the back bedroom. Manual D sizes every supply and return from the room loads and the blower you chose, then lays it out so your installers can follow it.

What it is

Manual D uses the room airflow from Manual J and the fan performance from Manual S to size trunks, branches, supplies and returns within the available static pressure.

We draw the layout on your plans and note the fitting and material assumptions, so the design and the install match. We run it in Wrightsoft, the industry-standard software for ACCA Manuals.

Manual T air distribution is included with every Manual D.

When you need it

IRC Section M1601.1 requires duct systems to be sized in accordance with ACCA Manual D. On new construction and additions, many plan reviewers ask for the duct layout with the load calculation.

Requirements vary by jurisdiction. Send us the project address and we will tell you what your building department typically asks for.

What we need from you

  • Floor plans with the air handler location
  • Your preferred duct material and system type
  • Filter type and size, so its pressure drop is included
  • Ceiling, attic or crawlspace constraints

What you receive

  • Duct layout drawn on your plans
  • Supply and return sizes with CFM per register
  • Friction rate and static pressure worksheet
“I can't say enough good things about LoadCalcs.net. I am building an HVAC system and they helped design a ducting system that would ensure maximum efficiency for my equipment and my home. They have been there to answer any dumb question I've had.”
GLGuerrero L. · Google review

Questions

Can you design for rigid, flex or duct board?

Yes. Tell us what you plan to install before we start, including the filter. Material and filter both change the pressure budget, and we design to what you will actually build.

Do you design commercial ductwork?

Yes. Light-commercial duct design follows ACCA Manual Q. Ask for it with a Manual N.

Do I need Manual T as well?

It is included. Manual T selects and places the registers and grilles, and it comes with every Manual D we design.

Fast estimates

Send the plans. Get an estimate.

Send us your questionnaire and plans, and we’ll get you an estimate right away. Reach out during office hours and you’ll hear back within 30 minutes, whether it’s an email, text or call.

Fast estimate

Drop your plans. Get an estimate.

PDF or photos of the plan set. Pick your services and send.

    Services

    Reach out during office hours and you’ll hear back within 30 minutes, whether it’s an email, text or call. Have every detail handy? Fill out the full project questionnaire.